PACCAR MX (2004 Emissions) Fault Code: P1024 BPV Actuator Power Supply – Incorrect
PACCAR MX (2004 Emissions) Fault Code: P1024 BPV Actuator Power Supply – Incorrect
SET CONDITIONS:
The BPV valve (L096) detects that the actuator power supply is less than 7.5 V or greater than 35 V.
DIAGNOSTIC CONDITION:
This diagnostic runs continuously when the ignition is on.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive:
1. After the ignition is keyed off for at least 15 seconds and keyed on again and
2. When the actuator power supply is between 8.5 V and 34 V
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. Incorrect actuator power supply wiring
2. Malfunction in vehicle power supply system (battery or alternator or wiring)
ADDITIONAL INFORMATION:
1. The actuator power supply is continuously monitored.
2. The actuator motor is switched off and the BPV valve is fully open (100% position) with this DTC active.
3. Engine torque is reduced after 10 hours of engine operation.
-
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5
-
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
JOHN DEERE SERVICE ADVISOR 5.3.225 DATABASE AG + CF ENGLISH 2023
John Deere $250.00Rated 0 out of 5
Related products
-
SERVICE MANUAL 3000 AND 4000 SERIES GEN 4 GENERATION – ALLISON
Allison$19.00Original price was: $19.00.$17.00Current price is: $17.00.Rated 0 out of 5 -
SERVICE MANUAL International Engines VT275 (2004 & Older)
INTERNATIONAL ENGINES $21.00Rated 0 out of 5