PACCAR MX (2004 Emissions) Fault Code: P1220 Injector Solenoid Valve Cylinder 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A9)
PACCAR MX (2004 Emissions) Fault Code: P1220 Injector Solenoid Valve Cylinder 2 – Voltage Too High or Short Circuit to Supply on ECU (D420) Pin (A9)
SET CONDITIONS:
The PCI ECU (D420) detects a too high voltage or a short circuit to supply on the ECU pin A9 circuit.
DIAGNOSTIC CONDITION:
This diagnostic runs when the engine is running.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive when the fault is no longer detected. To enable the injector output, the DTC must be cleared.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
Short circuit to supply in the circuit of ECU pin A9
ADDITIONAL INFORMATION:
The injector output is disabled by the PCI ECU when this DTC is detected. The output stays disabled until the DTC is cleared.
-
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5
-
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5 -
download Hitachi Construction Machinery MPDr Ver 3.7.0.0 [10.2020] Diagnostic Software
Hitachi $76.00Rated 0 out of 5 -
CLAAS WebTIC Offline [11.2021] Service Information – ENGLISH Language
CLAAS $100.00Rated 0 out of 5 -
volvo Devtool Studio V2 / V3 / V4 Developer tool plus 2.6 / 2.7
Trucks software $35.00Rated 0 out of 5 -
CAT CDVR PC Software – Caterpillar Digital Voltage Regulator (CDVR) WINDOWS 10
CAT $45.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Eaton Fuller – Autoshift, Autoselect Service Manual (TRSM-0050)
EATON $25.00Rated 0 out of 5