PACCAR PX-6 CM2150 (2007-09) Fault Code: 2273 PID: 411 SPN: 411 FMI: 3 Exhaust Gas Recirculation Valve Delta Pressure Sensor Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage detected at the EGR differential pressure sensor circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
Possible causes:
1)An open return circuit in the engine harness, connectors, or sensor
2)A signal wire shorted to sensor supply or battery voltage
3)A damaged EGR differential pressure sensor.
Possible repairs:
1)Replace the EGR valve delta pressure sensor.
2)Repair or replace the engine harness.
3)Replace the ECM.
Categories DTC TRUCKS, PACCAR, PX-6 CM2150 (2007-09)
Tags -, 2007-09, 2273, 3, 411, Above, at, Circuit, Circuit., CM2150, Code, Delta, Detected, Differential, EGR, Exhaust, Fault, FMI, Gas, High, Normal, or, PACCAR, PID, Pressure, PX-6, Recirculation, Sensor, Shorted, signal, Source., SPN, the, to, Valve, Voltage
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00 -
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P2771 Four-Wheel Drive Switch Circuit
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: U1041 J1850 (Class 2) ABS Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00