PACCAR PX-9 CM2350 (2013-17) Fault Code:1887 PID:2202 SPN:3226 FMI:4 Aftertreatment 1 Outlet NOx Sensor Circuit – Voltage Below Normal or Shorted to Low Source

Reason:
Aftertreatment Outlet NOx Sensor Circuit – Voltage Below Normal or Shorted to Low Source. An internal circuit error has been detected by the aftertreatment outlet NOx sensor.

Effect:
Possible reduced engine performance

Circuit Description:
The aftertreatment outlet NOx (nitrogen oxides) sensor is a smart device and communicates with the engine control module (ECM) via the J1939 data link. The aftertreatment outlet NOx sensor performs its own internal diagnostics and reports malfunctions back to the primary ECM using the J1939 data link. The NOx sensor is permanently attached to the NOx control module. They are serviced as a single component and can not be replaced individually. The aftertreatment outlet NOx sensor is used to measure the NOx emissions at the outlet of the aftertreatment system.

Component Location:
The aftertreatment outlet NOx sensor location can vary depending on engine application. It is usually located in the exhaust system at the outlet of the selective catalytic reduction (SCR) catalyst.

Conditions for Running the Diagnostics:
This diagnostic runs when the aftertreatment SCR outlet temperature has been above 200°C [392° F] for a calibratible period of time while the engine is running.

Conditions for Setting the Fault Codes:
An internal circuit error was detected in the aftertreatment outlet NOx sensor assembly.

Action Taken When the Fault Code is Active:
1) The ECM illuminates the amber CHECK ENGINE lamp and/or the Malfunction Indicator Lamp (MIL) immediately when the diagnostic runs and fails.
2) Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code:
1) To validate the repair, start and operate the engine to raise exhaust temperatures. This can be done by either driving the vehicle or initiating a stationary regeneration using INSITE™ electronic service tool.
2) The aftertreatment SCR outlet temperature must be above 200° C [392° F] for 60 seconds before the aftertreatment outlet NOx sensor can run its internal diagnostics.
3) The fault code status displayed by INSITE™ electronic service tool will change to INACTIVE immediately after the diagnostic runs and passes.
4) The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
5) For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
6) The Reset All Faults command in INSITE™ electronic service tool can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

Shop Talk:
Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Possible Causes:
1) The aftertreatment outlet NOx sensor has malfunctioned or is damaged
2) The aftertreatment outlet NOx sensor internal heater has malfunctioned
3) The NOx sensor part number is incorrect