This diagnostic function monitors the aftertreatment DPF temperature sensors and DPF soot level during normal operation. Based upon the operating conditions and DPF soot level the ECU decides if the engine should be de-rated in order to protect the DPF system components.
This diagnostic trouble code (DTC) can only occur during normal operating conditions, aftertreatment diesel particulate filter (DPF) regeneration process not active. In some cases extreme driving conditions can cause soot in the DPF to oxidize at an unacceptable rate and cause DPF damage.
Conditions for diagnostic trouble code (DTC):
1) Overheating the DPF due to soot oxidation during extreme driving conditions
2) Aftertreatment diesel particulate filter (DPF) exhaust temperatures are higher than expected for the existing conditions
Observable symptoms
1) Low Power
Probable cause
1) Extreme driving conditions
2) Regeneration inhibited, driver has not allowed regeneration to take place
3) Regeneration process is not functioning
4) Charge air system leakage
5) Aftertreatment Hydrocarbon Doser, Leakage
6) Discharge recirculation valve open
Detailed information
1) Activation
2) Engine de-rated, medium to high
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
Volvo Impact 2021 Trucks & Buses 06.2021 DVD 9116 Spare Parts Catalog
Trucks software $55.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.30 Developer + Devtool + INSTALATION VIDEO!
Trucks software $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P0973 Shift Solenoid 1 (SS1) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0974 Shift Solenoid 1 (SS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0979 Shift Solenoid 3 (SS3) Control Circuit – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2723 Pressure Control Solenoid 1 (PCS1) – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2686 Actuator Supply Circuit Voltage 3 High (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0980 Shift Solenoid 3 (SS3) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 3510 FMI 8 (CPC) 2-Channel Accelerator Pedal Supply Voltage Missing
DD16 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 558 FMI 4 (CPC) Short to Ground or an Open Wire
DD16 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 986 FMI 19 (CPC) Signal Source #1 or #2 is Erratic
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P101E11 PID: EMS Transmission Gate Interlock Valve
All Engines (2013 Emissions)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 5927 FMI 7 (MCM) Cooling System Performance Defect
DD16 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 598 FMI 2 (CPC) Clutch Switch Not Plausible
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 3482 FMI 5 (MCM) Fuel Cut-Off Valve Circuit Failed Open
DD13 EPA07 (2007-09)Rated 0 out of 5