This diagnostic function indicates malfunction at the exhaust gas temperature (EGT) sensor. The purpose of the exhaust gas sensor is to contribute the relevant temperatures required for the temperature regulated aftertreatment diesel particulate filter regeneration control. A faulty EGT sensor can result with a failed aftertreatment (DPF) regeneration.
Conditions for diagnostic trouble code (DTC):
1) The sensor value is not within an expected range
2) Too high of temperature difference compared to the other DPF temperature sensors
Observable symptoms
1) Regeneration not possible
Probable cause
1) Exhaust system leakage
2) Aftertreatment exhaust gas temperature (EGT) sensors installed in the incorrect location on the aftertreatment diesel particulate filter (DPF)
3) Wiring harness
4) Connector
5) Post aftertreatment diesel particulate filter (DPF), Exhaust Gas Temperature (EGT) Sensor
-
DAF Davie Runtime v5.6.1 Davie XDc ll [02.2019] + Expire Fix 302.00 Unlock ( Windows 7 )
DAF $70.00Rated 0 out of 5 -
CAT Engine Reprogramming Tool for flash programming C1.8, C2.4, C3.8 & C3.3B + Guide
CAT $50.00Rated 0 out of 5 -
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2669 Actuator Supply Voltage 2 Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2671 Actuator Supply Voltage 2 (HSD2) – High (Batt)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2670 Actuator Supply Voltage 2 (HSD2) – Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 524290 FMI 1 (ACM) This Diagnostic is a Test
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3663 FMI 3 (MCM) Injector Cylinder #5 Amplifier Control Valve Abnormal Operation (Max)
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 164 FMI 21 (MCM) Fuel Rail Pressure Sensor Drift Low
DD13 EPA07 (2007-09)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 164 FMI 0 (MCM) Quantity Control Valve High Side Driver Error
DD15 GHG14 (2014-16)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P2228 Internal ECU Ambient Pressure – Malfunction
MX (2004 Emissions)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P242B64 PID: EMS Exhaust Gas Temperature Sensor Circuit Range/Performance (Bank 1 Sensor 3)
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 5444 FMI 1 (MCM) Engine Crankcase Breather Oil Separator Speed Too Low
DD13 EPA10 (2010-13)Rated 0 out of 5 -
Cummins ISB CM550 (1990-94) Fault Code: 143-SW PID: 100 SPN: 100 FMI: 1 Oil Pressure Switch Circuit
CumminzRated 0 out of 5