This diagnostic trouble code (DTC) indicates malfunction at the aftertreatment diesel particulate filter (DPF) flame temperature sensor. This aftertreatment DPF flame temperature sensor is used to measure engine exhaust gas temperature (EGT) within the flame region of the aftertreatment DPF during aftertreatment DPF regeneration. The aftertreatment control module (ACM) monitors this temperature to detect the existence of the flame. Diagnostic trouble codes (DTCs) may result if the system is unable to light the flame or if there are multiple flame losses. Aftertreamemt DPF regeneration will be prevented until the system is sufficiently warmed-up for the specified duration.
Conditions for diagnostic trouble code (DTC):
1) **Flame Temperature Sensor is not within expected range**
Observable symptoms
1) Regeneration aborted
Probable cause
1 )Flame temperature sensor
2) Exhaust system leakage
3) Exhaust Gas Temperature (EGT) Sensor
4) Basic checks
5) The recommendation is to perform the following checks before any further fault tracing is performed
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P203D00 PID: ACM Aftertreatment Reagent Level Short Circit High
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P065713 PID: ACM Actuator Supply Voltage “A”
All Engines (2013 Emissions) -
PACCAR MX (2004 Emissions) Fault Code: P1675 PCI ECU – Software Error
MX (2004 Emissions) -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 1624 FMI 9 (CPC) Message is Missing
DD13 EPA10 (2010-13)