“DETROIT DIESEL DIAGNOSTIC LINK DDDL 8.20 SP1 2025” has been added to your cart. View cart
The aftertreatment fuel pump is controlled by the aftertreatment control module (ACM). The ACM supplies voltage to the aftertreatment fuel pump. The aftertreatment fuel pump supplies fuel from the vehicles fuel system through the fuel shutoff valve to the aftertreatment diesel particulate filter (DPF) atomization module.
Conditions for diagnostic trouble code (DTC):
1) Aftertreatment fuel pressure above normal value
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Fuel Pump
2) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
3) Chassis Harness
4) Aftertreatment Control Module (ACM)