The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
2) Aftertreatment selective catalytic reduction (SCR) catalyst warming not possible
Probable cause
1) Connector
2) Short circuit to voltage supply, Control wire (+)
3) Engine wiring harness
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P208A12 PID: ACM Reductant Pump “A” Control
All Engines (2017 Emissions) -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 97 FMI 15 (MCM) Water-In-Fuel Warning
DD15 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P05E311 PID: EMS Park Brake Sensor/Switch Circuit
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P24B500 PID: EMS Particulate Matter Sensor Heater Control Circuit Low
All Engines (2017 Emissions)