The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
2) Aftertreatment selective catalytic reduction (SCR) catalyst warming not possible
Probable cause
1) Connector
2) Short circuit to voltage supply, Control wire (+)
3) Engine wiring harness
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P220012 PID: EMS NOx Sensor Bank 1 Sensor 1
All Engines (2017 Emissions) -
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 14 PID: SPN: 122 FMI: 5 Med/High Retarder current low
3406E (Prefix 1MM or 2WS) -
Volvo All Engines (2017 Emissions) Fault Code: P21CAA1 PID: ACM Reductant Control Module Supply Voltage
All Engines (2017 Emissions) -
PACCAR MX (2004 Emissions) Fault Code: U17C8 CAN – Message (TSC1_VXR) Time-Out
MX (2004 Emissions) -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 168 FMI 1 (ACM) Battery Voltage Low
DD16 GHG14 (2014-16)