This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Regeneration failed to start
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Ignition wire connections
2) Nozzle
3) Aftertreatment diesel particulate filter (DPF) Ignition electrode(s)
4) Aftertreatment Fuel Supply Pressure
5) Flame temperature sensor
6) Aftertreatment ignition coil
7) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
8) Supplemental air valve
9) Low turbocharger boost
10) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
11) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P115100 PID: EMS Aftertreatment System Over Temperature
All Engines (2017 Emissions) -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 100 FMI 0 (MCM) Oil Pressure Stuck
DD13 GHG14 (2014-16) -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 3603 FMI 9 (CPC) ESS Message is Missing
DD16 EPA10 (2010-13)