This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Regeneration failed to start, Multiple occurrences
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Ignition wire connections
2) Nozzle
3) Aftertreatment diesel particulate filter (DPF) Ignition electrode(s)
4) Aftertreatment Fuel Supply Pressure
5) Aftertreatment fuel shut-off valve
6) Flame temperature sensor
7) Aftertreatment ignition coil
8) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
9) Low turbocharger boost
10) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
11) Aftertreatment Control Module (ACM)
-
Bobcat Service Library [03.2019] Service, Operator, Maintenance, Bulletines, etc full update
Bobcat $110.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
Navistar international OnCommand service information 2018 software trucks
Navistar $50.00Rated 0 out of 5 -
PF Diagnose 2.0.2.23 Diagnostics Software 2013 – Full Heavy & Medium Duty with OBDII Support – Online Installation Service
PF Diagnose $60.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2684 Actuator Supply Circuit Voltage 3 Open (HSD3)
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0977 Shift Solenoid 2 (SS2) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0980 Shift Solenoid 3 (SS3) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P097C Shift Solenoid 3 (SS3) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0122 Pedal Position Sensor Circuit – Low Voltage
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2727 Pressure Control Solenoid 1 (PCS1) Control Circuit – Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2670 Actuator Supply Voltage 2 (HSD2) – Low
1000 & 2000 Gen 5Rated 0 out of 5
-
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4334 FMI 3 (ACM) Diesel Exhaust Fluid Pressure Sensor Circuit Failed High
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 5361 FMI 18 (MCM) Cylinder #4 Engine Smoothness Control/Quantity Excess
DD16 GHG14 (2014-16)Rated 0 out of 5 -
Volvo Engine D11L (Tier 4) Fault Code: PID 105 FMI 0 Intake Manifold Temperature
D11L (Tier 4)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P02D100 PID: EMS Cylinder 3 fuel Injector Offset Learning At Max Limit
All Engines (2013 Emissions)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P033531 PID: EMS Crankshaft Position Sensor “A”
All Engines (2013 Emissions)Rated 0 out of 5 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0840 Transmission Pressure Switch Solenoid C Circuit
1000 & 2000 Gen 4 $50.00Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 3509 FMI 4 (ACM) The 5V Sensor Supply Bank 1 Circuit Failed Low
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 2003 FMI 9 PID: PSID 205 Transmission Control Module (TCM) Status
All Engines (2010 Emissions)Rated 0 out of 5 -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 4356 FMI 5 (ACM) Line Heater 3 Open Circuit
DD15 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 4193 FMI 3 (MCM) Engine Coolant Inlet Temperature Circuit Failed High
DD13 GHG14 (2014-16)Rated 0 out of 5