This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Regeneration failed to start, Multiple occurrences
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Ignition wire connections
2) Nozzle
3) Aftertreatment diesel particulate filter (DPF) Ignition electrode(s)
4) Aftertreatment Fuel Supply Pressure
5) Aftertreatment fuel shut-off valve
6) Flame temperature sensor
7) Aftertreatment ignition coil
8) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
9) Low turbocharger boost
10) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
11) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 91 FMI 13 (CPC) Data Out of Calibration
DD13 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P110F9E PID: EMS Engine Stop Switch Stuck
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 1074 FMI 4 PID: Engine (Exhaust) Brake Output
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P100111 PID: EMS Engine Stop Switch
All Engines (2017 Emissions) -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 986 FMI 9 (CPC) CM1 Message is Missing
DD15 EPA10 (2010-13)