During DPF regeneration the Aftertreatment Fuel Pressure Sensor monitors the fuel pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. During Air Purge the Aftertreatment Fuel Pressure Sensor monitors the air pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. The Engine Control Module (ECM) uses this input to determine if the system is operating correctly.
Conditions for diagnostic trouble code (DTC):
1) The sensor signal is not rational
2) Aftertreatment fuel pressure below Placeholder, aftertreatment fuel shutoff valve open
Observable symptoms
1) Regeneration not possible
2) Regeneration aborted
Probable cause
1) Air in the fuel system
2) Aftertreatment fuel shut-off valve, Stuck in one position
3) Fuel filter
4) De-aeration valve
5) Overflow valve
6) Fuel pump
Detailed information
1) This DTC will only set during an aftertreatment DPF service regeneration
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P00C600 PID: EMS Fuel Rail Pressure Too Low – Engine Cranking
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P20FE00 PID: ACM Aftertreatment Reagent Pump Control Build Up Failure
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P229F64 PID: EMS NOx Sensor Gas Outlet Removed
All Engines (2013 Emissions)