During DPF regeneration the Aftertreatment Fuel Pressure Sensor monitors the fuel pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. During Air Purge the Aftertreatment Fuel Pressure Sensor monitors the air pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. The Engine Control Module (ECM) uses this input to determine if the system is operating correctly.
Conditions for diagnostic trouble code (DTC):
1) The sensor signal is not rational
2) Aftertreatment fuel pressure below Placeholder, aftertreatment fuel shutoff valve open
Observable symptoms
1) Regeneration not possible
2) Regeneration aborted
Probable cause
1) Air in the fuel system
2) Aftertreatment fuel shut-off valve, Stuck in one position
3) Fuel filter
4) De-aeration valve
5) Overflow valve
6) Fuel pump
Detailed information
1) This DTC will only set during an aftertreatment DPF service regeneration
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
PACCAR MX (2004 Emissions) Fault Code: P1678 PCI ECU – Software Error
MX (2004 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P26E800 PID: ACM Actuator Supply Voltage “D”
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P204A13 PID: ACM Reductant Pressure Sensor
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P204F93 PID: ACM SCR System Performance Dosing Failure
All Engines (2013 Emissions)