The aftertreatment control module (ACM) supplies a pulsed ground signal to activate the ignition coil. The ignition coil is connected to the ignition electrodes by two ignition wires. When activated it supplies 40,000 to 45,000 volts to the ignition electrodes creating an arc that ignites the atomized fuel and air mixture in the aftertreatment diesel particulate filter (DPF) combustion chamber of the aftertreatment DPF.
Conditions for diagnostic trouble code (DTC):
1) Pin: 13 (Control wire (-)), Short circuit to ground
Observable symptoms
1) Regeneration not possible
Probable cause
1) Wiring harness between Aftertreatment ignition coil and Aftertreatment Control Module (ACM)
2) Aftertreatment ignition coil
3) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P110186 PID: EMS Reductant Tank Temperature Sensor Circuit Electrical
All Engines (2017 Emissions) -
Volvo All Engines (2004 Emissions) Fault Code: PID 224 FMI 12 Immobilizer
All Engines (2004 Emissions) -
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 61 PID: SPN: 110 FMI: 0 High Coolant Temperature Warning
3406E (Prefix 1MM or 2WS) -
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 61 PID: 110 SPN: FMI: 0 High Coolant Temperature Warning
3406E (Prefix 5DS or 1LW) -
Volvo All Engines (2013 Emissions) Fault Code: P01162A PID: EMS Engine Coolant Temperature Circuit Range/Performance
All Engines (2013 Emissions) -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 628 FMI 14 (CPC) XFLASH Failure
DD15 EPA10 (2010-13)