The aftertreatment diesel particulate filter (DPF) atomization air pressure sensor is used to monitor the pressure of the compressed air supply to the aftertreatment DPF atomization module during active diagnostics and measures the combined atomization fuel and air pressure during burner operation. The sensor consists of a pressure sensitive diaphragm/amplifier sensor. Air pressure causes the sensors diaphragm to deflect and produce an electrical signal proportional to the pressure. The diaphragm deflection signal is amplified in the sensor.
Conditions for diagnostic trouble code (DTC):
1) Atomization air pressure above normal value with aftertreatment diesel particulate filter (DPF) air shutoff valve closed and aftertreatment DPF atomization air valve open during active diagnostics
Observable symptoms
1) Regeneration not possible
Probable cause
1) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Diesel Particulate Filter (DPF) Air shutoff Valve)
2) Aftertreatment DPF Atomization Air Pressure Sensor
3) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Aftertreatment DPF Atomization Air Actuator)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P040311 PID: EMS EGR “A” Control
All Engines (2013 Emissions) -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 628 FMI 14 (CPC) XFLASH Failure
DD13 EPA10 (2010-13) -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 98 FMI 18 (CPC) Low Engine Oil Level
DD16 GHG14 (2014-16) -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 2631 FMI 1 (MCM) Low Air Flow
DD16 GHG14 (2014-16)