The aftertreatment diesel particulate filter (DPF) combustion air valve is controlled by the aftertreatment control module (ACM) output. The combustion air valve is normally closed and is opened when a ground signal is supplied by the ACM to the combustion air valve solenoid. When opened, charged air from the intake manifold is supplied through the combustion air valve to the aftertreatment DPF combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:33 is above normal value
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1 )Regeneration not possible
Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Connector
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment DPF Combustion Air Solenoid
6) Aftertreatment Control Module (ACM)
-
John Deere & Hitachi Parts ADVISOR 2020 [08.2020] Offline DVD Spare Parts Catalog
John Deere $120.00Rated 0 out of 5 -
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2637 Torque Management Feedback Signal – SEM
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2789 Clutch Adaptive Learning at Limit
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2723 Pressure Control Solenoid 1 (PCS1) – Stuck Off
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1891 Throttle Position Sensor (TPS) PWM Signal – Low Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1790 Gear Shift Module 1 Calibration Invalid
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P0122 Pedal Position Sensor Circuit – Low Voltage
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2730 Pressure Control Solenoid 1 (PCS1) Control Circuit – High
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P1892 Throttle Position Sensor (TPS) PWM Signal – High Input
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5Rated 0 out of 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2724 Pressure Control Solenoid 1 (PCS1) – Stuck On
1000 & 2000 Gen 5Rated 0 out of 5
-
Volvo All Engines (2017 Emissions) Fault Code: P024600 PID: EMS Wastegate Short Circuit High
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD16 GHG14 (2014-16) Fault Code: SPN 1636 FMI 2 (MCM) Engine Air Temperature – Plausibility Fault Out of Range (Low Box)
DD16 GHG14 (2014-16)Rated 0 out of 5 -
PACCAR MX (2004 Emissions) Fault Code: P228E Common Rail Fuel Pressure Control – Incorrect
MX (2004 Emissions)Rated 0 out of 5 -
Volvo All Engines (2017 Emissions) Fault Code: P220093 PID: EMS NOx Sensor Bank 1 Sensor 1
All Engines (2017 Emissions)Rated 0 out of 5 -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 4077 FMI 14 (MCM) Hydrocarbon Doser Fuel Line Pressure Failed Self – Test
DD15 GHG14 (2014-16)Rated 0 out of 5 -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 4337 FMI 3 (ACM) Diesel Exhaust Fluid Metering Unit Temperature – Drift
DD15 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 1326 FMI 31 (MCM) Idle Smoothness Control/Cylinder #4 Misfire at Idle
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Eaton Gen 2 (AutoShift) Fault Code: 51 PID: 60 FMI: 3 Rail Select Sensor
DTC TRUCKSRated 0 out of 5 -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 2791 FMI 15 (MCM) High Load Operation in High Ambient Temperatures
DD15 EPA07 (2007-09)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P113C00 PID: EMS Turbo Compound Buffer Air Valve Control Circuit High
All Engines (2013 Emissions)Rated 0 out of 5