The aftertreatment diesel particulate filter (DPF) combustion air valve is controlled by the aftertreatment control module (ACM) output. The combustion air valve is normally closed and is opened when a ground signal is supplied by the ACM to the combustion air valve solenoid. When opened, charged air from the intake manifold is supplied through the combustion air valve to the aftertreatment DPF combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:33 is above normal value
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1 )Regeneration not possible
Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Connector
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment DPF Combustion Air Solenoid
6) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P040399 PID: EMS EGR “A” Control
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P007164 PID: EMS Ambient Air Temperature Sensor Range/Performance
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P112900 PID: EMS Transmission Fluid Temperature Moderately High
All Engines (2013 Emissions) -
Detroit DD15 EPA10 (2010-13) Fault Code: SPN 1639 FMI 2 (MCM) Fan Speed Error
DD15 EPA10 (2010-13) -
Volvo Engine D12D AE E3 (Tier 3) Fault Code: PID100 FMI 1 Engine Oil Pressure
D12D AE E3 (Tier 3) -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 1624 FMI 9 (CPC) Message is Missing
DD13 EPA10 (2010-13)