The aftertreatment diesel particulate filter (DPF) combustion air valve is controlled by the aftertreatment control module (ACM) output. The combustion air valve is normally closed and is opened when a ground signal is supplied by the ACM to the combustion air valve solenoid. When opened, charged air from the intake manifold is supplied through the combustion air valve to the aftertreatment DPF combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:33 is above normal value
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1 )Regeneration not possible
Probable cause
1) Short circuit to voltage supply, Control wire (-)
2) Connector
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment DPF Combustion Air Solenoid
6) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 97 FMI 15 (MCM) Water-In-Fuel Warning
DD13 GHG14 (2014-16) -
Volvo All Engines (2017 Emissions) Fault Code: P204264 PID: ACM Reductant Temperature Sensor
All Engines (2017 Emissions) -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 98 FMI 18 (CPC) Low Engine Oil Level
DD13 GHG14 (2014-16) -
Volvo All Engines (2017 Emissions) Fault Code: P026D00 PID: EMS Fuel Injection Quantity Higher Than Expected
All Engines (2017 Emissions)