The atomization air valve is part of the atomization module and the combustion air valve is located on the engine. Both are controlled by the same DPF ECU output. The valves are normally closed and are opened when voltage is supplied by the DPF ECU. When opened, compressed air supplied from the air tank through the priority valve is supplied through the atomization air valve to the atomization nozzle while charged air from the intake manifold is supplied through the combustion air valve to the DPF Unit combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:29 is above normal value
Probable cause
1) Wiring harness between Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve and Aftertreatment Control Module (ACM)
2) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
3) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
4) DPF Control Unit
5) Basic checks
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P009511 PID: EMS Intake Air Temperature Sensor 2 Bank 1
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P20E892 PID: EMS Reductant Pressure Too Low
All Engines (2013 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P220093 PID: EMS NOx Sensor Bank 1 Sensor 1
All Engines (2013 Emissions)