The atomization air valve is part of the atomization module and the combustion air valve is located on the engine. Both are controlled by the same DPF ECU output. The valves are normally closed and are opened when voltage is supplied by the DPF ECU. When opened, compressed air supplied from the air tank through the priority valve is supplied through the atomization air valve to the atomization nozzle while charged air from the intake manifold is supplied through the combustion air valve to the DPF Unit combustion chamber.
Conditions for diagnostic trouble code (DTC):
1) Open circuit
Observable symptoms
1) Regeneration not possible
Probable cause
1) Open circuit, Control wire (-)
2) Open circuit, Common voltage supply
3) Aftertreatment diesel particulate filter (DPF) wiring harness, below raceway
4) Chassis Harness
5) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module (Aftertreatment DPF Atomization Air Actuator)
6) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P06B317 PID: EMS Sensor Power Supply “B”
All Engines (2017 Emissions) -
PACCAR MX (2004 Emissions) Fault Code: U179E CAN – Message (TSC1 xxe) Time-Out
MX (2004 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P25AB00 PID: EMS Piston Cooling Oil Control Circuit High
All Engines (2013 Emissions)