The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1) Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Allison 1000 & 2000 Gen 5 Fault Code:P0731 Incorrect 1st Gear Ratio
1000 & 2000 Gen 5 -
Volvo All Engines (2010 Emissions) Fault Code: SPN 100 FMI 2 PID: 100 Engine Oil Pressure
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P030200 PID: EMS Cylinder 2 Misfire Detected
All Engines (2013 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 171 FMI 19 PID: 171 Ambient Air Temperature
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P054500 PID: ACM Exhaust Gas Temperature Short Circuit Low
All Engines (2017 Emissions)