The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
Diagnostic operating conditions
1 )Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P242A11 PID: ACM Exhaust Gas Temperature Sensor Bank 1 Sensor 3
All Engines (2017 Emissions) -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 625 FMI 9 (ACM) Heartbeat Missing
DD13 GHG14 (2014-16) -
Detroit DD16 EPA07 (2007-09) Fault Code: SPN 647 FMI 5 (MCM) Fan Open Circuit
DD16 EPA07 (2007-09) -
Volvo All Engines (2017 Emissions) Fault Code: P01B913 PID: EMS Engine Oil temperature Sensor “B”
All Engines (2017 Emissions)