The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
2) Diagnostic operating conditions
3) Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P066601 PID: EMS Control Module Internal Temperature Sensor “A”
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P205A64 PID: EMS Reductant Tank Temperature Sensor
All Engines (2017 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P11497E PID: EMS Intake Air Heater “B” Circuit
All Engines (2013 Emissions)