The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Voltage above normal or shorted high
2) Diagnostic operating conditions
3) Output activated
Observable symptoms
1) Regeneration not possible
Probable cause
1) Connector
2) Engine wiring harness
3) Aftertreatment Hydrocarbon Dosing Module
4) Engine control module (ECM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P020256 PID: EMS Cylinder 2 Injector “A”
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P018564 PID: EMS Fuel Temperature Sensor “B”
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 653 FMI 12 PID: SID 3 Engine Injector Cylinder 3
All Engines (2010 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 3491 FMI 5 PID: Aftertreatment DPF Atomization Air Actuator
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P048011 PID: EMS Fan 1 Control Circuit
All Engines (2017 Emissions)