The following components are connected to a common 12?V supply
R31: Aftertreatment Diesel Exhaust Fluid (DEF) Line Heater 1
R29: Aftertreatment Diesel Exhaust Fluid (DEF) Line Heater 3
A138: Aftertreatment Diesel Exhaust Fluid (DEF) Return Valve
A138: Aftertreatment Diesel Exhaust Fluid (DEF) Pump Motor
Y81: Aftertreatment Diesel Exhaust Fluid (DEF) Tank Heater Valve
If an abnormal voltage or current is detected on the common supply a DTC is set
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:44 is above normal value
Observable symptoms
1) None
Probable cause
1) Wiring harness
2) Connector
3) R31: Aftertreatment Diesel Exhaust Fluid (DEF) Line Heater 1
4) R29: Aftertreatment Diesel Exhaust Fluid (DEF) Line Heater 3
5) A138: Aftertreatment Diesel Exhaust Fluid (DEF) Return Valve
6) A138: Aftertreatment Diesel Exhaust Fluid (DEF) Pump Motor
7) Y81: Aftertreatment Diesel Exhaust Fluid (DEF) Tank Heater Valve
8) A137: Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 69 PID: 26 SPN: FMI: 5 Auxiliary Output #01 current low
3406E (Prefix 5DS or 1LW) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 103 FMI 15 PID: Engine Turbocharger – Least Severe Level
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P117F11 PID: EMS Hydraulic Fan Bypass Valve
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P027000 PID: EMS Cylinder 4 Injector Circuit Low
All Engines (2017 Emissions) -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 4334 FMI 7 (ACM) DEF Pressure Low
DD16 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P040C00 PID: EMS Exhaust Gas Recirculation Temperature Sensor “A”
All Engines (2017 Emissions)