Volvo All Engines (2010 Emissions) Fault Code: SPN 4375 FMI 14 PID: PSID 121 Aftertreatment Diesel Exhaust Fluid Pump (DEF) Driver Percentage
The aftertreatment control module (ACM) uses the aftertreatment diesel exhaust fluid (DEF) dosing pressure sensor value to adjust and maintain DEF pressure at the DEF dosing valve by controlling DEF pump speed. If the pressure decreases below expected value when the pump is in initial pressure build-up mode or if the pressure increases above expected value when pump is in idle speed mode, the ACM considers DEF pressure outside of normal operating range and indicates a malfunction in a DEF dosing pressure sensor.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A137:9 is below normal value
Observable symptoms
1) No aftertreatment diesel exhaust fluid (DEF) dosage
Probable cause
1) Open circuit, Common voltage supply
2) Short circuit to ground, Common voltage supply
3) Wiring harness
4) Aftertreatment Diesel Exhaust Fluid (DEF) Pump
5) Aftertreatment Control Module (ACM)
Detailed information
1) Possible engine de-rate
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 21 PID: SPN: 232 FMI: 3 5 Volt Supply voltage high
3406E (Prefix 1MM or 2WS) -
Volvo All Engines (2017 Emissions) Fault Code: P208E00 PID: EMS Aftertreatment Reagent Dosing Valve Clogged
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 108 FMI 4 PID: Barometric Pressure
All Engines (2010 Emissions) -
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 26 PID: SPN: 108 FMI: 3 Atmospheric Pressure voltage high
3406E (Prefix 1MM or 2WS) -
Volvo All Engines (2013 Emissions) Fault Code: P204213 PID: ACM Reductant Temperature Sensor
All Engines (2013 Emissions) -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 558 FMI 3 (CPC) Open Circuit
DD13 EPA07 (2007-09)