ECM – 4815, Fan clutch
Electronic Viscous Fan: The Electronic Fan Drive contains a solenoid that controls the flow of fluid between reservoirs in the fan drive housing and cover. The Engine Control Module (ECM) provides a (PWM) Pulse Width Modulation signal to the solenoid and controls solenoid operation to optimize fan speed, based on coolant temperature, intake air temperature and A/C load.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A14.EA:26 is below normal value
Observable symptoms
1) The fan will rotate at full speed at low engine speed
2) At high engine speeds, the fan will either be disengaged or run at low fan speed
Probable cause
1) Wiring harness
2) Connector
3) Solenoid valve, engine fan
-
Eaton Service Ranger 4.9 Engineering 4.9 [05.2021] Engineering Level ( 1 PC )
Eaton $67.00Rated 0 out of 5 -
premium volvo tech tool update 2.8.150 diagnostic software 1pc
Trucks software $150.00Rated 0 out of 5 -
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
JPRO 2022 v1 Commercial Vehicle Diagnostics V1 Software Download & Installation Service ( 1 PC )
JPRO $94.00Rated 0 out of 5
Related products
-
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 174 FMI 3 (MCM) Supply Fuel Temperature Sensor Open Circuit
DD13 GHG14 (2014-16)Rated 0 out of 5 -
Volvo All Engines (2013 Emissions) Fault Code: P249C00 PID: EMS Excessive Time to Enter Closed Loop Reductant Injectile Control
All Engines (2013 Emissions)Rated 0 out of 5 -
Detroit DD13 EPA10 (2010-13) Fault Code: SPN 164 FMI 4 (MCM) Fuel Rail Pressure Sensor Circuit Failed Low (Short to Ground)
DD13 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 164 FMI 1 (MCM) Quantity Control Valve Low Side Driver Error
DD16 EPA10 (2010-13)Rated 0 out of 5 -
Detroit DD13 GHG14 (2014-16) Fault Code: SPN 651 FMI 7 (MCM) Injector Cylinder #1 Needle Control Valve Stuck Open
DD13 GHG14 (2014-16)Rated 0 out of 5