The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Air pressure, not within expected range
Observable symptoms
1) Regeneration not possible
Probable cause
1) Low air pressure
2) Aftertreatment Hydrocarbon Dosing Module
3) Inconsistent Air pressure
4) Fuel line(s), Leakage
5) Aftertreatment Fuel Pressure Sensor
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 46 PID: 100 SPN: FMI: 1 Low Oil Pressure Warning
3406E (Prefix 5DS or 1LW) -
Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID2 FMI 3 Injector #2
D12D AE E3 (Tier 3)