The Aftertreatment Hydrocarbon Dosing Module contains three non serviceable valves, the Aftertreatment Fuel Shutoff Valve, Aftertreatment Purge Air Valve and Aftertreatment Hydrocarbon Dosing Valve, and a serviceable Aftertreatment Fuel Pressure Sensor.
During DPF regeneration the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Fuel Shutoff Valve to the open position. This allows fuel to flow into the Aftertreament Hydrocarbon Dosing Module. The Aftertreatment Fuel Pressure Sensor monitors the fuel pressure value and sends a reference signal to the ECM. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that regulates the amount of fuel delivered to the Aftertreatment Hydrocarbon Doser through the air/fuel line.
During Air Purge operation the Engine Control Module (ECM) sends a voltage signal to activate the Aftertreatment Purge Air Valve open. This allows air pressure to flow into the Aftertreament Hydrocarbon Dosing Module. The ECM then sends a PWM signal to the Aftertreatment Hydrocarbon Dosing Valve that allows purge air pressure to be monitored by a signal from the Aftertreatment Fuel Pressure Sensor to the ECM.
Conditions for diagnostic trouble code (DTC):
1) Aftertreatment Fuel Pressure, not within expected range
2) Fuel leakage
Observable symptoms
1) Regeneration not possible
2) Probable cause
3) Aftertreatment Hydrocarbon Dosing Module
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P040984 PID: EMS EGR Differential Pressure Sensor
All Engines (2013 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P052200 PID: EMS Engine Oil Pressure Circuit Low
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P009A00 PID: EMS Engine Air Intake Temperature – Correlation
All Engines (2017 Emissions) -
Detroit DD13 EPA07 (2007-09) Fault Code: SPN 713 FMI 4 (CPC) Short to Ground Circuit
DD13 EPA07 (2007-09)