Cummins ISB CM850 (2003-06) Fault Code: 2384 (ISC) PID: SID 27 SPN: 641 FMI: 4 VGT Actuator – Voltage Below Normal or Shorted to Low Source. Low voltage detected at turbocharger control valve circuit.
Cummins ISB CM850 (2003-06) Fault Code: 2384 (ISC) PID: SID 27 SPN: 641 FMI: 4 VGT Actuator – Voltage Below Normal or Shorted to Low Source. Low voltage detected at turbocharger control valve circuit.
Turbocharger control valve command can be monitored with the INSITE? electronic service tool. This parameter represents the ECM command to the turbocharger control valve which in turn controls the variable geometry actuator position.
Possible causes:
1)Signal short circuit to ground
2)Short circuit to ground in the turbocharger control valve.
Possible repairs:
1)Replace the turbocharger control valve.
2)The removal and installation of the connector may correct the fault.
3)Replace the ECM.
4)Repair or replace the engine harness