Cummins ISB6.7 CM2150 (2007-09) Fault Code: 115 PID: 115 SPN: 115 FMI: 2 Engine Magnetic Speed/Position Lost Both of Two Signals – Data Erratic, Intermittent, or Incorrect. The engine control module (ECM) has detected that the primary and backup speed sensor signals are connected backwards.
Verify the ECM calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM.
This fault code indicates that the camshaft position sensor and crankshaft position sensor wiring harness connectors are reversed.
Possible repairs:
1)If necessary, calibrate the ECM.
2)Replace the ECM.
Categories Cumminz, DTC TRUCKS, ISB6.7 CM2150 (2007-09)
Tags 2007-09, and, are, backup, backwards., Both, CM2150, Code115, connected, Control, Cummins, Data, Detected, ECM, Engine, Erratic, Fault, FMI2, has, Incorrect, Intermittent, ISB6.7, Lost, Magnetic, Module, of, or, PID115, primary, Sensor, Signals, Speed, Speed/Position, SPN115, that, the, Two
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0873 Transmission Pressure Switch Solenoid E Circuit High
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1300 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00