Cummins ISC CM2150 (2007-09) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Fuel Pump Pressurizing Assembly 1 Circuit – Voltage Above Normal or Shorted to High Source. High signal voltage or open circuit detected at the fuel pump actuator circuit.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM. If necessary, recalibrate the ECM.
This fault becomes active when the ECM detects an open in the fuel pump actuator circuit. Causes of this fault code are a short circuit to a positive voltage or an open circuit in the fuel pump actuator circuit. If there is high harness resistance or an intermittent open circuit, Fault Code 2311 can have high inactive counts. If the fault code is intermittent, look for causes of an intermittent open circuit such as loose pins and bad connections. If the fault code is intermittent, look closely for loose wire connections at the ECM connector. Also, if the fault code is intermittent, wiggle the harness and the electronic fuel control.
Possible repairs:
1)Replace the fuel pump actuator.
2)Repair or replace the engine harness
3)Replace the ECM.
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P0876 Transmission Reverse Pressure Switch Circuit Stuck Open
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0218 Transmission Fluid Over Temperature Condition
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0122 Pedal Position Sensor Circuit Low Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00