Cummins ISC CM2150 (2007-09) Fault Code: 2777 PID: 390 SPN: 3703 FMI: 11 Particulate Trap Active Regeneration Inhibited Due to Permit Switch – Condition Exists. Regeneration of the diesel particulate filter has been prevented due to the permit switch being disabled.
Verify the electronic control module (ECM) calibration is correct. Check the calibration revision history found on QuickServe® Online for applicable fixes to the calibration stored in the ECM.
If this fault code is active and there has been damage to the aftertreatment system, the permit switch may have prevented the aftertreatment system from performing a mobile (active) regeneration. Consult with the OEM if the aftertreatment system has failed due to the permit switch.
Possible repairs:
1)If necessary, recalibrate the ECM.
-