Cummins ISL CM850 (2003-06) Fault Code: 237 PID: SID 30 SPN: 644 FMI: 2 External Speed Command Input (Multiple Unit Synchronization) – Data Erratic, Intermittent, or Incorrect. The throttle input signal to the primary or secondary engine for multiple unit synchronization is less than 3 percent or more than 97 percent.
Cummins ISL CM850 (2003-06) Fault Code: 237 PID: SID 30 SPN: 644 FMI: 2 External Speed Command Input (Multiple Unit Synchronization) – Data Erratic, Intermittent, or Incorrect. The throttle input signal to the primary or secondary engine for multiple unit synchronization is less than 3 percent or more than 97 percent.
The J1939 datalink connections are part of the OEM harness. Location of the J1939 harness will vary by the OEM. Refer to the OEM manual for specific component location.
The configuration of the three pins inputs to the electronic control module (ECM) on the OEM harness determines if an engine is a primary or secondary engine. To activate a pin, the pin must be grounded. To deactivate a pin, the pin must be open circuit.
Possible repairs:
1)Repair or replace the OEM harness.
-
DOWNLOAD Paccar ESA Electronic Service Analyst 5.5.0 Diagnostic Software 2023
PACCAR $96.00Rated 0 out of 5 -
PACCAR Electronic Service Analyst 5.4.3.0 SW files 27.03.2021 software trucks
PACCAR $60.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5
-
CAT ET 2021A (Caterpillar Electronic Technician) + Factory Password (1 PC )
CAT $65.00Rated 0 out of 5 -
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
Wabco ToolBox plus 13.7 + ECAS CAN2 v3.00 Diagnostics Software
Trucks software $84.00Rated 0 out of 5
Related products
-
SERVICE MANUAL INTERNATIONAL ENGINE VT275 (2005 & Newer)
INTERNATIONAL ENGINES $27.00Rated 0 out of 5