Cummins ISL CM850 (2003-06) Fault Code: 386 PID: SID 212 SPN: 1079 FMI: 3 Sensor Supply Voltage number 1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 1 circuit.

Cummins ISL CM850 (2003-06) Fault Code: 386 PID: SID 212 SPN: 1079 FMI: 3 Sensor Supply Voltage number 1 Circuit – Voltage Above Normal or Shorted to High Source. High voltage detected at sensor supply number 1 circuit.

High voltage on the sensor supply line can be caused by an individual sensor supply wire in the harness shorted to battery voltage or a failed ECM power supply.

On-Board Diagnostics (OBD) Information (Euro 4 Certified Engines):

1)The ECM illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails.
2)The ECM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. The MIL lamp and fault code can also be cleared using the INSITE? service tool.
3)The fault code will be cleared from memory after 40 consecutive drive cycles where the diagnostic runs and passes.

On-Board Diagnostics (OBD) Information (Euro 4 Stage 1+ Certified Engines):

1)The ECM illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails.
2)An engine torque derate will be activated after 50 hours of engine operation with the fault code active.
3)The ECM turns OFF the malfunction indicator lamp (MIL) after 1 ignition cycle that the diagnostic runs and does not fail. The MIL lamp cannot be cleared using the INSITE? service tool.
4)The fault code will be cleared from memory after 400 days or 9600 hours of engine operation.

Possible repairs:

1)Repair or replace the engine harness.
2)Replace the ECM.
3)Repair or replace the OEM harness.