Cummins ISM CM875 (2003-06) Fault Code: 2274 PID: P411 SPN: 411 FMI: 4/4 Exhaust Gas Recirculation Valve Delta Pressure Sensor Circuit – Voltage Below Normal or Shorted to Low Source. Low signal voltage detected at the EGR differential pressure sensor circuit.
The EGR differential pressure sensor shares supply and return wires in the engine harness with other sensors. Opens and shorts in the engine harness can cause multiple fault codes to be active. Before troubleshooting Fault Code 2274, check for multiple faults.
Possible causes:
1)Signal circuit open in the engine harness, connectors, or sensor
2)Supply circuit open or shorted to ground
3)Leaks in the sensor EGR differential pressure tubes
4)Sensor shorted to ground.
Possible repairs:
1)Repair the exhaust leaks at the pressure tubes.
2)Replace the EGR differential pressure sensor.
3)Repair the damaged harness, connector, or pins.
4)Replace the ECM.
Categories Cumminz, DTC TRUCKS, ISM CM875 (2003-06)
Tags -, 2003-06, 2274, 4/4, 411, at, Below, Circuit, Circuit., CM875, Code, Cummins, Delta, Detected, Differential, EGR, Exhaust, Fault, FMI, Gas, ISM, Low, Normal, or, P411, PID, Pressure, Recirculation, Sensor, Shorted, signal, Source., SPN, the, to, Valve, Voltage
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1000 Class 2 Loss of Serial Data Communication
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P1779 Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P0123 Pedal Position Sensor Circuit High Voltage
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0032 J1850 (Class 2) Serial Data Communication Link High
1000 & 2000 Gen 4 $50.00