Cummins ISM CM875 (2003-06) Fault Code: 431 (SSS) PID: S230 SPN: 558 FMI: 2/2 Accelerator Pedal Idle Validation Circuit – data incorrect. Voltage detected simultaneously on both idle validation and off-idle validation switches.
SSS Goes to 70-fc431sss
Possible causes:
1)A open circuit on either the idle validation on-idle or off-idle signal circuits, a loose connection, uncalibrated accelerator pedal assembly, or miswired idle validation switch.
2)Since the solid state sensor switch (SSS) uses an integrated circuit to output idle and off-idle SIGNALs, the internal resistance can not be checked with a multimeter as it is for the integrated sensor switch and nonintegrated sensor switch.
3)When installing a new accelerator pedal assembly, it must be calibrated before operating the engine. To calibrate, turn the keyswitch to the ON position and fully depress and release the pedal three times.
Possible repairs:
1)Connect the SSS to the OEM harness.
2)Replace the SSS.
3)Repair or replace the OEM harness.
4)Replace the ECM.
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 4 Fault Codes: U1064 J1850 (Class 2) TBC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: P2773 Torque Control Request Ignored – ECM/TCM
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U0031 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00 -
Allison 1000 & 2000 Gen 4 Fault Codes: U1096 J1850 (Class 2) IPC Controller State of Health Failure
1000 & 2000 Gen 4 $50.00 -
Bendix ABS EC-30 Fault Code: SID 251 FMI 3
Bendix ABS -
Allison 1000 & 2000 Gen 4 Fault Codes: P1688 Unmanaged Engine Torque Delivered To TCM Signal
1000 & 2000 Gen 4 $50.00