Cart $0.00
0
0
Subtotal: $0.00
No products in the cart.

Cummins ISX15 CM2250 (2010-12) Fault Code: 3375 (BCL) PID: SID 115 SPN: 5397 FMI: 31 Aftertreatment Diesel Particulate Filter Regeneration Too Frequent- Condition Exists

Circuit Description
The engine control module (ECM) records the time from the completion of an active regeneration of the aftertreatment DPF until the ECM requests another active regeneration of the DPF.

Component Location
The aftertreatment DPF mounting location is dependent on the original equipment manufacturer (OEM). Refer to the OEM service manual.

Conditions for Running the Diagnostics
This diagnostic runs after completion of a successful active regeneration of the aftertreatment DPF.

Conditions for Setting the Fault Codes
The time between the completion of a successful active regeneration and the request for another active regeneration is less than a threshold.

Action Taken When the Fault Code is Active
The ECM illuminates the amber CHECK ENGINE lamp and/or malfunction indicator lamp (MIL) after the diagnostic fails on two consecutive trips.

Conditions for Clearing the Fault Code
To validate the repair using a Diagnostic Road Test, utilize a route that incorporates both stop-and-go city driving and steady-state highway driving. It may be necessary to load the unit for certain diagnostics in the ECM to run.
To validate the repair using a Chassis Dynamometer Test, utilize a routine that incorporates acceleration and motoring events, steady-state highway operation, and load. This will simulate normal driving and allow the diagnostics in the ECM to run.
For On-Board Diagnostics (OBD) engines, the ECM will turn off the MIL after three consecutive trips where the diagnostic runs and passes.
The “Reset All Faults” command in INSITE? electronic service tool can be used to clear active and inactive fault codes, as well as turn OFF the MIL for OBD applications.

Shop Talk
Possible causes of this fault code include:

Malfunctioning aftertreatment temperature sensor(s)
Malfunctioning or stuck in-range aftertreatment DPF pressure sensor
An engine malfunction resulting in high engine out smoke
Damaged or malfunctioning OEM wiring harness to the differential pressure sensor
Aftertreatment DPF with excessive ash accumulation caused by lubricating oil consumption or coolant consumption.
An excessive ash accumulation condition reduces the soot holding capability of the DPF and will cause frequent aftertreatment regenerations. This condition may exist if one or more of the following requirements are met:

Troubleshooting tree for Fault Code 3375 or 3376 has been exhausted with no fault found.
Ash cleaning is required at less than the recommended DPF ash cleaning interval. Reference the ISX15 CM2250 Owners Manual, Bulletin 2883360, or the ISX12/ISX11.9 CM2250 Owners Manual, Bulletin 2883443.
Multiple vehicles from the same fleet experience an issue with Fault Code 3375 or 3376 within a short period of time.
If excessive ash accumulation is found in the DPF, reference the Aftertreatment Diesel Particulate Filter – Excessive Ash Cleaning troubleshooting symptom tree in Section TS in the ISX15 CM2250 Service Manual, Bulletin 4022250, or in the ISX12/ISX11.9 CM2250 Service Manual, Bulletin 2883445.

Possible Cause:
1) ECM calibration
2) Aftertreatment DPF differential pressure sensor failure
3) EGR differential pressure sensor ports
4) DPF failure