PACCAR MX (2004 Emissions) Fault Code: P0A1F PCI ECU Power Supply – Data Valid but Too Low
PACCAR MX (2004 Emissions) Fault Code: P0A1F PCI ECU Power Supply – Data Valid but Too Low
SET CONDITIONS:
The PCI ECU (D420) detects that the power supply is less than 10 V.
DIAGNOSTIC CONDITION:
This diagnostic runs continuously after starting and running the engine.
CORRESPONDING OBD READINESS MONITOR:
None
RESET CONDITION:
This DTC changes to inactive when the fault is no longer detected.
REPAIR VERIFICATION:
1. Clear all DTCs.
2. Test drive or operate the vehicle to meet the diagnostic conditions and set conditions.
3. Did the DTC come back?
– No, repair successful
– Yes, repair unsuccessful
POSSIBLE CAUSES:
1. Alternator malfunctioning
2. PCI ECU power supply
ADDITIONAL INFORMATION:
For this diagnostic, the PCI ECU monitors its power supply only during engine operation to detect a running voltage drain-down. It does not detect a cranking voltage drain-down.
-
download MANCATS II v14.01 2014 Diagnostic software MAN CATS ( virtual machine )
MAN $75.00Rated 0 out of 5
-
VOLVO PREMIUM TECH TOOL PTT 2.7.116 + APCI 2021 + devtool ( ONLINE )
Trucks software $80.00Rated 0 out of 5 -
Volvo Intermediate Storage File Encryptor/Decryptor (Editor) VISFED 0.3.2
Trucks software $35.00Rated 0 out of 5 -
International Truck ISIS – Oncommand Service Information Q4.2020 [04.2020]
Navistar $85.00Rated 0 out of 5 -
ddct Detroit diesel calibration tool (DDCT) v4.5 English Include Calibrations & Metafiles
Detroit $30.00Rated 0 out of 5 -
DETROIT DDDL 8.14 SP3 – Detroit Diesel Diagnostic Link 8.14 SP3 2021 ( 1PC )
Detroit $73.00Rated 0 out of 5 -
Hino Diagnostic eXplorer 2 – Hino DX2 1.1.19.1 with keygen unlocked ( Hino trucks )
Hino $50.00Rated 0 out of 5
Related products
-
SERVICE MANUAL Carrie Genesis R70 Genesis R90 Genesis TR1000 Multi -Temp
CARRIE $25.00Rated 0 out of 5