This diagnostic function indicates malfunction at the exhaust gas temperature (EGT) sensor. The purpose of the exhaust gas sensor is to contribute the relevant temperatures required for the temperature regulated aftertreatment diesel particulate filter regeneration control. A faulty EGT sensor can result with a failed aftertreatment (DPF) regeneration.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A14.EB:47 is less than 1.08?V
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
Probable cause
1) Wiring harness between component connector and electronic control unit (ECU) connector
2) Short circuit to ground, Signal wire
3) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P047012 PID: EMS Exhaust Pressure Sensor “A”
All Engines (2013 Emissions) -
PACCAR MX (2004 Emissions) Fault Code: P0121 Accelerator Pedal – Sticking Pedal
MX (2004 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P250F00 PID: EMS Engine Oil Level Circuit Too Low
All Engines (2017 Emissions) -
Volvo All Engines (2010 Emissions) Fault Code: SPN 1127 FMI 11 PID: PSID 98 Engine Turbocharger 1 Boost Pressure
All Engines (2010 Emissions) -
Volvo All Engines (2013 Emissions) Fault Code: P24B000 PID: EMS Particulate Matter Sensor Circuit Low
All Engines (2013 Emissions)