This diagnostic function indicates malfunction at the exhaust gas temperature (EGT) sensor. The purpose of the exhaust gas sensor is to contribute the relevant temperatures required for the temperature regulated aftertreatment diesel particulate filter regeneration control. A faulty EGT sensor can result with a failed aftertreatment (DPF) regeneration.
Conditions for diagnostic trouble code (DTC):
1) The voltage at pin A14.EB:43 is less than 1.08?V
Diagnostic operating conditions
1) Ignition key in ON position
Observable symptoms
1) Regeneration not possible
Probable cause
1) Wiring harness between component connector and electronic control unit (ECU) connector
2) Short circuit to ground, Signal wire
3) Aftertreatment Control Module (ACM)
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2761 TCC PCS Control Circuit Open
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5
-
Volvo All Engines (2010 Emissions) Fault Code: SPN 3464 FMI 12 PID: Engine Throttle Actuator 1 Control Command
All Engines (2010 Emissions) -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 986 FMI 9 (CPC) CM1 Message is Missing
DD16 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P269712 PID: EMS Exhaust Aftertreatment Fuel Injector “A”
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P20DD01 PID: EMS Exhaust Aftertreatment Fuel Supply Control
All Engines (2017 Emissions) -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 713 FMI 3 (CPC) Short to Power
DD15 EPA07 (2007-09) -
Volvo All Engines (2013 Emissions) Fault Code: P113F11 PID: EMS Buffered Idle Validation Switch Wire – VECU Side
All Engines (2013 Emissions)