This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P242A15 PID: ACM Exhaust Gas Temperature Sensor Bank 1 Sensor 3
All Engines (2017 Emissions) -
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 91 FMI 4 (CPC) Circuit Failed Low
DD16 EPA10 (2010-13) -
Volvo All Engines (2017 Emissions) Fault Code: P204B00 PID: ACM Aftertreatment Reagent PumpOrifice Orifice Blocked
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P020B25 PID: EMS Cylinder 2 Injection Timing
All Engines (2017 Emissions)