This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0100 Lost Communication With ECM A
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2013 Emissions) Fault Code: P03351F PID: EMS Crankshaft Position Sensor “A”
All Engines (2013 Emissions) -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 636 FMI 14 (MCM) Swapped Pins
DD15 GHG14 (2014-16) -
Volvo All Engines (2013 Emissions) Fault Code: P204B00 PID: ACM Aftertreatment Reagent PumpOrifice Orifice Blocked
All Engines (2013 Emissions) -
Allison 1000 & 2000 Gen 4 Fault Codes: U1301 J1850 (Class 2) Serial Data Communication Link Low
1000 & 2000 Gen 4 $50.00