This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2764 TCC PCS Control Circuit Low
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
Detroit DD16 EPA10 (2010-13) Fault Code: SPN 98 FMI 18 (CPC) Low Engine Oil Level
DD16 EPA10 (2010-13) -
Volvo All Engines (2013 Emissions) Fault Code: P260513 PID: EMS Intake Air Heater “B” Control
All Engines (2013 Emissions) -
Detroit DD15 EPA07 (2007-09) Fault Code: SPN 2791 FMI 4 (MCM) Circuit Failed Low
DD15 EPA07 (2007-09) -
Volvo All Engines (2013 Emissions) Fault Code: P24B000 PID: EMS Particulate Matter Sensor Circuit Low
All Engines (2013 Emissions)