This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Multiple lost flames
Probable cause
1) No spark
2) Aftertreatment ignition coil
3) Ignition wire connections
4) Aftertreatment fuel system
5) Aftertreatment Hydrocarbon Doser
6) Aftertreatment diesel particulate filter (DPF) combustion air valve
7) Aftertreatment diesel particulate filter (DPF) air supply
8) Aftertreatment Diesel Particulate Filter (DPF) Air shutoff Valve Solenoid
-