This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Flame temperature: Temperature too high
2) Flame temperature: Temperature too low
Probable cause
1) Aftertreatment diesel particulate filter (DPF) combustion air valve
2) Aftertreatment fuel system
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0074 CAN Communications BUS 2 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2010 Emissions) Fault Code: SPN 631 FMI 4 PID: PSID 124 Calibration memory
All Engines (2010 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P109541 PID: EMS Aftertreatment Control Unit
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P040984 PID: EMS EGR Differential Pressure Sensor
All Engines (2017 Emissions) -
CAT 3406E (Prefix 1MM or 2WS) Fault Code: 62 PID: SPN: 111 FMI: 11 Very Low Coolant Level
3406E (Prefix 1MM or 2WS) -
Volvo Engine D12D AE E3 (Tier 3) Fault Code: SID2 FMI 7 Injector #2
D12D AE E3 (Tier 3) -
Volvo All Engines (2017 Emissions) Fault Code: P262611 PID: EMS O2 Sensor Positive Current Trim Bank 1 Sensor 1
All Engines (2017 Emissions)