This fault indicates failure of the combustion flame to ignite. When aftertreatment diesel particulate filter (DPF) regeneration is active the aftertreatment control module (ACM) activates the ignition coil, aftertreatment DPF atomization module and air valves in order to create a flame in the aftertreatment DPF combustion chamber. The flame temperature is monitored continually by the ACM. To verify combustion the ACM measures the rise in flame temperature during the first 10 seconds of combustion. If proper combustion during the first 10 seconds of operation is not achieved the fault will be set.
Conditions for diagnostic trouble code (DTC):
1) Regeneration failed to start
Observable symptoms
1) Regeneration aborted
2) Regeneration not possible
Probable cause
1) Ignition wire connections
2) Nozzle
3) Aftertreatment diesel particulate filter (DPF) Ignition electrode(s)
4) Aftertreatment Fuel Supply Pressure
5) Flame temperature sensor
6) Aftertreatment ignition coil
7) Aftertreatment Diesel Particulate FIlter (DPF) Combustion Air Valve
8) Supplemental air valve
9) Low turbocharger boost
10) Aftertreatment Diesel Particulate Filter (DPF) Atomization Module
11) Aftertreatment Control Module (ACM)
-
2021 VOLVO PREMIUM TECH TOOL PTT V2.8.21 VCADS+DEVELOPER TOOL+APCI 2021/09 ( 1 PC )
Trucks software $85.00 -
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5
-
Volvo All Engines (2017 Emissions) Fault Code: P260200 PID: EMS Coolant Pump “A” Control Circuit Low
All Engines (2017 Emissions) -
Volvo All Engines (2017 Emissions) Fault Code: P203900 PID: ACM Reductant Injection Air Pressure Sensor “A”
All Engines (2017 Emissions)