During DPF regeneration the Aftertreatment Fuel Pressure Sensor monitors the fuel pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. During Air Purge the Aftertreatment Fuel Pressure Sensor monitors the air pressure rise and drop in the Aftertreament Hydrocarbon Dosing Module. The Engine Control Module (ECM) uses this input to determine if the system is operating correctly.
Conditions for diagnostic trouble code (DTC):
1) The sensor signal is not rational
2) Aftertreatment fuel pressure below Placeholder, aftertreatment fuel shutoff valve open
Observable symptoms
1) Regeneration not possible
2) Regeneration aborted
Probable cause
1) Air in the fuel system
2) Aftertreatment fuel shut-off valve, Stuck in one position
3) Fuel filter
4) De-aeration valve
5) Overflow valve
6) Fuel pump
Detailed information
1) This DTC will only set during an aftertreatment DPF service regeneration
-
Volvo Premium Tech Tool PTT 2.8.130 Diagnostic Software 04.2022 ACPI ( 1 PC )
Trucks software $143.00
Related products
-
Allison 1000 & 2000 Gen 5 Fault Code:U0073 CAN Communication Bus 1 Off
1000 & 2000 Gen 5 -
Allison 1000 & 2000 Gen 5 Fault Code:P2763 TCC PCS Control Circuit High
1000 & 2000 Gen 5
-
CAT 3406E (Prefix 5DS or 1LW) Fault Code: 25 PID: 102 SPN: FMI: 0 Excessive Boost Pressure
3406E (Prefix 5DS or 1LW) -
Volvo All Engines (2017 Emissions) Fault Code: P027000 PID: EMS Cylinder 4 Injector Circuit Low
All Engines (2017 Emissions) -
Detroit DD15 GHG14 (2014-16) Fault Code: SPN 100 FMI 1 (CPC) Oil Pressure Very Low
DD15 GHG14 (2014-16) -
Volvo All Engines (2013 Emissions) Fault Code: P203D00 PID: EMS Aftertreatment Reagent Level Short Circuit High
All Engines (2013 Emissions)